Ensurepass

12. RAID
12.1 Overview
Stands for Redundant Array of Inexpensive Disks or Redundant Array of Independent Disks. It uses multiple disks to increase performance and/or reduce the chances of data loss due to hardware failure.
12.2 Supported Versions
1. Striping (RAID 0)
o No Redundancy
o Fastest read/write performance.
o Requires 2 or more disks.
2. Mirroring (RAID 1)
o Requires 2 or more disks.
o Fast read performance.
o Requires 2x actual storage size requirements.
3. Data and Parity Striping (RAID 5)
o Requires 3 or more disks.
o More efficient use of disk space than RAID 1.
12.3 Partition Type
Set partition type to 0xFD for auto detection of RAID devices (use option ‘t’ in fdisk).
12.4 Configuration File (/etc/raidtab)
See raidtab man page for an example.
Sample file:
### RAID 1
raiddev /dev/md0
raid-level 1 # Mirroring
nr-raid-disks 3 # Number of disks to use
nr-spare-disks 1 # Hot standby in case another fails
persistent-superblock 1 # Required for auto detection
chunk-size 32 # In KB

device /dev/hda3
raid-disk 0
device /dev/hdb3
raid-disk 1
device /dev/hde5
raid-disk 2
device /dev/hdc4
spare-disk 0

### RAID 5
raiddev /dev/md1
raid-level 5 # Data and parity striping
nr-raid-disks 3 # Number of disks to use
nr-spare-disks 1 # Hot standby in case another fails
persistent-superblock 1 # Required for auto detection
chunk-size 32 # In KB
parity-algorithm right-symmetric

device /dev/sda1
raid-disk 0
device /dev/sdb3
raid-disk 1
device /dev/sdc5
raid-disk 2
device /dev/sdd4
spare-disk 0
12.5 Initializing RAID devices
mkraid /dev/md0
mkraid /dev/md1
NOTE: mkraid also causes necessary RAID modules to be loaded by kernel as if raidstart had been executed.
12.6 Formatting RAID devices
mke2fs -b 4096 -R stride=8 /dev/md0
mke2fs -b 4096 -R stride=8 /dev/md1
“-R” is used to set RAID related options for the file system. Stride is the number of blocks per chunk. In the previous examples we are using a 32K chunk size with a 4K block size, so stride has to be 8 (4K * 8 = 32K).
12.7 RAID 5 parity options
Specify parity algorithm with the “parity-algorithm” option in /etc/raidtab. Possible values are:
1. left-asymmetric
2. right-asymmetric
3. left-symmetric
4. right-symmetric
Left-symmetric offers the maximum performance on typical disks with rotating platters.
12.8 Auto detection of RAID arrays
Requires:
1. Partition type must be set to 0xFD.
2. Auto detection must be turned on in kernel.
3. Must specify “persistent-superblock 1” in /etc/raidtab

Download the Ensurepass Latest 2013 RHCE EX300 Practise Test PDF to pass RHCE EX300 exam.