Latesttests
2018 Jan Oracle Official New Released 1z0-489
100% Free Download! 100% Pass Guaranteed!
http://www.Latesttests.com/1z0-489.html

SPARC M6-32 and SPARC M5-32 Servers Installation Essentials

Question No: 21

Which three options are memory population rules of the SPARC M5-32 server when mixing DIMMs?

  1. Populate each CMU with DIMMs of the same size or rank.

  2. Mix different DIMM sizes on different CMU boards in the same DCU.

  3. DIMMs in the same position (0, 1, 2, or 3) within a CMU must be homogeneous (that is, the sametype, same dram capacity, and same rank).

  4. Mixing of different DIMM sizes is allowed, as long as homogeneous types are populated per CPUsocket.

  5. When mixing DIMMs, large-sized DIMMs need to be put in position 0, 1, 2, or 3.

Answer: B,C,E

Question No: 22

Before you can configure the service processors, which three pieces of information do you need from the customer?

  1. SP0 IP address

  2. SP1 IP address

  3. domain IP address

  4. Active SP IP address

  5. clock board IP address

Answer: A,C,D

Reference:

https://docs.oracle.com/cd/E19469-01/820-6413-13/IPMI_Overview.html

Question No: 23

When you perform a firmware upgrade at a customer’s site, what three things actually get updated?

  1. Oracle ILOM firmware

  2. OpenBoot PROM firmware

  3. POST firmware

  4. Oracle Solaris firmware

  5. Disk firmware

Answer: A,B,E

Reference:

https://docs.oracle.com/cd/E19464-01/820-6851-10/firmware.html

Question No: 24

Which three virtualization options or technologies are included in the SPARC M5-32 server?

  1. Hyper-V hypersior

  2. Physical domain (PDomain or PDom)

  3. LDom (that is, Oracle VM for SPARC)

  4. Oracle Solaris Zones (for OS virtualization)

  5. Oracle VMware

Answer: C,D,E

Reference:

http://www.oracle.com/technetwork/server-storage/sun-sparc- enterprise/documentation/o13-056-m5-domaining-1991544.pdf

Question No: 25

There are a total of 36 fan modules in the SPARC M5-32 server, and all are redundant and hot- swappable. Which statement is correct?

  1. Half of the 36x fan modules are located on the front and the other half on the rear. 18x fan modules are in front fan cages and 18x fan modules are in back fan cages.

  2. 36x fan modules are located on the front and rear; 12x fan modules are in front fan cages, 12x fan modules are in back middle fan cages, and 12x fan modules are in back lower fan cages.

  3. All 36x fan modules are located on the front, 16x fan modules in upper fan cages, 16xfan

    modules in lower fan cages, and 2x fan modules on each side (left and right next to the SP/SSB).

  4. All 36x fan modules are located on the front, 12x fan modules are In upper fan cages, 12x fan modules are in middle fan cages, and 12x fan modules are in lower fan cages.

Answer: A

Question No: 26

After completing an installation, you need to collect the system’s configuration. Which two actions do you perform?

  1. Explorer on the SPs

  2. Explorer on the PDoms

  3. Snapshot on the SPs

  4. Snapshot on the PDoms

Answer: B,D

Question No: 27

A customer with a SPARC M5-32 server believes it is not fully configured and wants to add more CMU boards to the platform. Which option represents ILOM targets that you can use to find out if the platform can accommodate additional CPUs?

  1. /SP/config/Processors

  2. /Servers/Processors

  3. /System/Processors

  4. /Systems/DCUs

Answer: C

Question No: 28

When SunVTS has completed its testing, where do you find the log files?

  1. /var/logs

  2. /var/sunvts/logs

  3. /var/adm/sunvts/messages

  4. /var/sunvts/messages

Answer: B

Reference:

https://docs.oracle.com/cd/E19469-01/819-4363-12/sunvts_diag_x4540.html

Question No: 29

There, unbounded PDoms and bounded PDoms on a SPARC M5-32 mm. which three statements are correct?

  1. Bounded PDoms have lower latency, and loss of any SSB has no effect.

  2. Bounded PDoms have lower latency. You can form a bounded PDom with I6x M5 CPUs, by

    combining 2x DCU.

  3. Unbounded PDoms are expandable beyond 8x M5 CPUs; and SSB stores L3$ directory for fasterlookup.

  4. Both an unbounded and a bounded PDom operate like an independent server that has full

    hardware isolation from other PDoms on the server.

  5. A PDom can be dynamically switched between bounded and unbounded.

Answer: A,D,E

Reference:

http://www.oracle.com/technetwork/server-storage/sun-sparc- enterprise/documentation/o13-024-m5-32-architecture-1920556.pdf

Question No: 30

Before turning the system over to a customer, you want to verify that both SPs are functional. Which action do you perform to test the failover?

  1. Set /SP/failover on.

  2. Start /SP/failover.

  3. Set /SP/redundancy failover=true.

  4. Set /SP/redundancy initiate_ failover_ action=true

Answer: D

Reference:

https://docs.oracle.com/cd/E19720-01/820-1188-12/core_ilom_managing.html

100% Free Download!
Download Free Demo:1z0-489 Demo PDF
100% Pass Guaranteed!
Download 2018 Latesttests 1z0-489 Full Exam PDF and VCE

Latesttests ExamCollection Testking
Lowest Price Guarantee Yes No No
Up-to-Dated Yes No No
Real Questions Yes No No
Explanation Yes No No
PDF VCE Yes No No
Free VCE Simulator Yes No No
Instant Download Yes No No

2018 Latesttests IT Certification PDF and VCE

Comments are closed.